LandCode
Snellville › Unified Development Ordinance

Chapter 200 — Zoning and Land Use, Article 4 — Towne Center Districts

Code as publishedas of 2025-03-10
Our copylast checked 2026-10-19 · re-check pendingA newer version is published (amended through 2026-01-12). Our copy does not yet carry it.
StatusOfficial
Verify with City of Snellville ↗2 sections · full chapter
§ 204-1

TC-MU Towne Center Mixed-Use

Chapter 200. Zoning and Land Use Article 4. Towne Center Districts TC-MU Towne Center Mixed-Use Purpose Dimensional standards The purpose of this district is to provide for compact, mixed-use development in Snellville's core that supports the Towne Center's role as a focal point for the city. See Sec. 205-1.1 (TCO) for additional purposes.

Use Provisions See Sec. 206-2 (Allowed Use Table).

Site Development Standards See Chapter 200 Article 7 (Site Development) for parking and loading, buffer and screening, landscaping, tree ordinance, lighting, signs, and utility requirements.

Building Types Building type requirements apply in the TC-MU district and the following types are Site Standards allowed: Residential Density (by As approved by Detached house Special Use Permit): City Council Carriage house Min. Amenity Space 5% of site min.

Cottage court Requirement: (all sites)

Min. Civic Space 10% of site min.

Semi-detached house Requirement: (sites over 5 acres)

Townhouse Lot Standards Ⓐ Area Ⓑ Width Walk-up flat Detached House: 2,500 sf. 25 ft. min.

Stacked flat min.

Commercial house Carriage House: Same as principal structure Shopfront Semi-Detached House: 2,500 sf. 25 ft. min.

Mixed-use building min.

General building Townhouse: 800 sf. min. 20 ft. min.

Civic building Cottage Court: 1,200 sf. 20 ft. min.

min.

Architectural Standards All other Building 1,600 sf. 30 ft. min.

See Sec. 201-4 (Enhanced Architectural Types: min.

Standards). Lot Coverage Ⓒ All Building Types: 100% max.

Building Placement Building Setbacks Ⓐ Front Yard, Side (Street) (State route): 10 ft. min.

Ⓐ Front Yard, Side 5 ft. min.

(Street) (other):

Ⓑ Side Yard: 0 ft. min.

Ⓒ Rear Yard (no alley) 6 ft. min.

Ⓒ Rear Yard (alley): 3 ft. min.

Greater side setbacks, greater rear setbacks, and greater building separation may be required as established by the applicable building or fire codes.

Bulk and Mass Building Height Ⓐ Min. Height: 2 stories or 24 ft., whichever is greater Ⓐ Max. Height in Stories: 5 stories or 75 ft., whichever is less TCO Standards The Towne Center Overlay applies in the TC-MU District. See Sec. 205-1 (Towne Center Overlay).

§ 204-2

TC-R Towne Center Residential

TC-R Towne Center Residential Purpose.

The purpose of this district is to provide for a variety of housing options near the Towne Center’s mixed-use core. See Sec. 205-1.1 (TCO Purpose) for additional purposes.

Use Provisions See Sec. 206-2 (Allowed Use Table).

Site Development Standards See Chapter 200 Article 7 (Site Development) for parking and loading, buffer and screening, landscaping, tree ordinance, lighting, signs, and utility requirements.

Building Types Building type requirements apply in the TC-R district and the following types are allowed:

Detached house Carriage house Cottage court Semi-detached house Townhouse Walk-up flat Stacked flat Civic building Architectural Standards See Sec. 201-4 (Enhanced Architectural Standards).

Dimensional Standards Site Standards Residential Density (by As approved by Special Use Permit): City Council Amenity Space 5% of site min.

Requirement: (all sites)

Civic Space 10% of site min.

Requirement: (sites over 5 acres)

Lot Standards Ⓐ Area Ⓑ Width Detached House: 2,500 sf 25 ft.

Carriage House: Same as principal structure

Table or figure — shown as printedverify at source ↗
Semi-Detached House:      2,500 sf           25 ft.
Townhouse:                800 sf             20 ft.
Cottage Court:            1,200 sf           20 ft.
All other Building Types  1,600 sf           30 ft..

Lot Coverage Ⓒ All Building Types: 70% max.

Sec. 201-1.

Building Placement Building Setbacks

Table or figure — shown as printedverify at source ↗
Ⓐ Front, Side      (Street) :    5 ft. min.
Ⓑ Side  (Interior)     :         0 ft. min.
Ⓒ Rear      (no alley) :         3 ft. min.
Ⓒ Rear      (alley) :            10 ft. min.

Greater side setbacks, greater rear setbacks, and greater building separation may be required as established by the applicable building or fire codes.

Bulk and Mass Building Height Ⓐ Max. Height in Stories: 5 stories or 75 ft., whichever is less TCO Standards The Towne Center Overlay applies in the TC-R District. See Sec. 205-1 (Towne Center Overlay).

Sec. 201-1.

Article 5. Special and Overlay Districts Table of Contents

Table or figure — shown as printedverify at source ↗
Towne Center Overlay ................................................................................... 200-125

CI Civic/Institutional ...................................................................................... 200-135

FH Flood Hazard District ............................................................................... 200-137

Sec. 201-1.

[THIS PAGE INTENTIONALLY BLANK]